Built-in Modules

Built-in Modules 1.Transmitter accuracy achieves 0.05% 2.Support many types of thermal resistance and thermocouple sensors 3.Thermocouple can use cold end compensation function 4.Support 2/3/4-wire RTD connection mode 5.Safety isolation for bus and sensor

  • Hot
    M0310 MODBUS To HART Module

    M0310 MODBUS To HART Module

    MODBUS To HART Module/M0310 General Instroduction
    Microcyber Corporation has customized many built-in protocol converting modules for the majority of field device manufacturers, supporting to connect MODBUS RTU protocol (hereinafter referred to as “MODBUS” protocol) slave device into a variety of fieldbus system. The function of M0310 built-in MODBUS to HART module (hereinafter referred to as "HART module") is to convert MODBUS slave device into HART slave device.
    1. Comply with HART 7.9 protocol standard
    2. Support dynamic configuration of Modbus communication parameters
    3. Support 6 device variables and 4 dynamic variables

    Email Details
  • Hot
    MC0310 Modbus to HART Embedded Core Module

    MC0310 Modbus to HART Embedded Core Module

    The MC0310 is an OEM built-in module for converting Modbus RTU based instruments to HART. The MC0310 is one of the Microcyber MC series embedded core modules. This series of embedded core modules features the characteristics of same size, same interface, easy upgrade, and simple configuration. It can be widely used in various products such as transmitters, intelligent measuring equipment, instruments, and is an ideal choice for users to quickly develop fieldbus devices.
    1. Comply with HART 7.9 protocol standard
    2. Support dynamic configuration of Modbus communication parameters
    3. Support 6 device variables and 4 dynamic variables

    Email Details
  • Hot
    M0310-ACT Modbus to HART Actuator Embedded Module

    M0310-ACT Modbus to HART Actuator Embedded Module

    The M0310-ACT is an OEM actuator built-in module for converting Modbus RTU based instruments to HART. The M0310-ACT is one of the Microcyber M series embedded modules. This series of embedded modules features the characteristics of same size, same interface, easy upgrade, and simple configuration. It can be widely used in various products such as actuators and valve positioners, and is an ideal choice for users to quickly develop fieldbus devices.
    1. Comply with HART 7.9 protocol standard
    2. Support dynamic configuration of Modbus communication parameters
    3. Support 6 device variables, 1 actuator variable, and 4 dynamic variables

    Email Details
  • Hot
    M0307 MODBUS To PA Module

    M0307 MODBUS To PA Module

    The M0307 is an OEM built-in module for converting Modbus RTU based instruments to PROFIBUS PA. The M0307 is one of the Microcyber M series embedded modules. This series of embedded modules features the characteristics of same size, same interface, easy upgrade, and simple configuration. It can be widely used in various products such as transmitters, intelligent measuring equipment, instruments, and is an ideal choice for users to quickly develop fieldbus devices.
    1. Size: 42mm*65mm
    2. Comply with PA profile 3.02
    3. Support Modbus-RTU communication parameters dynamic configuration
    4. Support AI, AO, DI and DO function blocks
    5. Support up to 4 channels AI, AO, DI, DO

    Email Details
  • Hot
    M0313 MODBUS To FF Module

    M0313 MODBUS To FF Module

    M0313 MODBUS To FF Module.Modbus-FF built-in module realizes the conversion function from MODBUS Protocol to Foundation Fieldbus F1 Protocol.
    1. Size: 42mm*65mm
    2. Comply with FF H1 protocol
    3. Support Modbus-RTU communication parameters dynamic configuration
    4. Support AI, AO, DI, DO and PID function blocks
    5. Support ITK 6

    Email Details
  • Hot
    HART Module Modbus to HART Module

    HART Module Modbus to HART Module

    Microcyber Corporation (hereinafter referred to as “Microcyber”) has customized many built-in protocol converting modules for the majority of field device manufacturers, supporting to connect MODBUS RTU protocol (hereinafter referred to as “MODBUS” protocol) slave device into a variety of fieldbus system. The function of M0310 built-in MODBUS to HART module (hereinafter referred to as "HART module") is to convert MODBUS slave device into HART slave device.

    Email Details
  • Hot
    Modbus to DP Built-in Module

    Modbus to DP Built-in Module

    Modbus to DP Built-in Module is one of the Microcyber M-series embedded modules developed by Microcyber Corporation. This series of embedded modules have features like same size, same interface, easy to upgrade, easy configuration and so on, it is the ideal choice for users to quickly develop the fieldbus equipment.
    1. Comply with PROFIBUS DPv0 protocol standard
    2. DP slave address can be set via DIP switch
    3. Same hardware, M0006 custom protocol to DP module can be selected.

    Email Details
  • Hot
    Modbus to PA Built-in Module

    Modbus to PA Built-in Module

    Modbus to PA built-in module is one of the Microcyber M-series built-in modules developed by Microcyber Corporation. This series of built-in modules have features like same size, same interface, easy to upgrade, easy configuration and so on, and Modbus to PA built-in module is the ideal choice for users to quickly develop the fieldbus equipment.
    1. Size: 42mm*65mm
    2. Comply with PA profile 3.02
    3. Support Modbus-RTU communication parameters dynamic configuration
    4. Support AI, AO, DI and DO function blocks
    5. Support up to 4 channels AI, AO, DI, DO

    Email Details
  • Hot
    Modbus to FF Built-in Module

    Modbus to FF Built-in Module

    Modbus to FF Built-in Module realizes the conversion function from MODBUS Protocol to Foundation Fieldbus F1 Protocol. Modbus to FF Built-in Module is one of the Microcyber M-serise modules,which have features of same size,same interface,easy to upgrade and easy to configure

    Email Details
  • 1
  • 2
  • >
  • Total 13 Records
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy