Built-in Modules

Built-in Modules 1.Transmitter accuracy achieves 0.05% 2.Support many types of thermal resistance and thermocouple sensors 3.Thermocouple can use cold end compensation function 4.Support 2/3/4-wire RTD connection mode 5.Safety isolation for bus and sensor

  • Hot
    MODBUS To PA Module

    MODBUS To PA Module

    M0307 MODBUS To PA Module.M0307 Modbus to PA embedded module is one of the Microcyber M-series embedded modules developed by Microcyber Corporation.
    1. Size: 42mm*65mm
    2. Comply with PA profile 3.02
    3. Support Modbus-RTU communication parameters dynamic configuration
    4. Support AI, AO, DI and DO function blocks
    5. Support up to 4 channels AI, AO, DI, DO

    Email Details
  • Hot
    MODBUS To FF Module

    MODBUS To FF Module

    M0313 MODBUS To FF Module.Modbus-FF built-in module realizes the conversion function from MODBUS Protocol to Foundation Fieldbus F1 Protocol.
    1. Size: 42mm*65mm
    2. Comply with FF H1 protocol
    3. Support Modbus-RTU communication parameters dynamic configuration
    4. Support AI, AO, DI, DO and PID function blocks
    5. Support ITK 6

    Email Details
  • Hot
    HART Module Modbus to HART Module

    HART Module Modbus to HART Module

    Microcyber Corporation (hereinafter referred to as “Microcyber”) has customized many built-in protocol converting modules for the majority of field device manufacturers, supporting to connect MODBUS RTU protocol (hereinafter referred to as “MODBUS” protocol) slave device into a variety of fieldbus system. The function of M0310 built-in MODBUS to HART module (hereinafter referred to as "HART module") is to convert MODBUS slave device into HART slave device.

    Email Details
  • Hot
    Modbus to DP Built-in Module

    Modbus to DP Built-in Module

    Modbus to DP Built-in Module is one of the Microcyber M-series embedded modules developed by Microcyber Corporation. This series of embedded modules have features like same size, same interface, easy to upgrade, easy configuration and so on, it is the ideal choice for users to quickly develop the fieldbus equipment.

    Email Details
  • Hot
    Modbus to PA Built-in Module

    Modbus to PA Built-in Module

    Modbus to PA built-in module is one of the Microcyber M-series built-in modules developed by Microcyber Corporation. This series of built-in modules have features like same size, same interface, easy to upgrade, easy configuration and so on, and Modbus to PA built-in module is the ideal choice for users to quickly develop the fieldbus equipment.
    1. Size: 42mm*65mm
    2. Comply with PA profile 3.02
    3. Support Modbus-RTU communication parameters dynamic configuration
    4. Support AI, AO, DI and DO function blocks
    5. Support up to 4 channels AI, AO, DI, DO

    Email Details
  • Hot
    Modbus to FF Built-in Module

    Modbus to FF Built-in Module

    Modbus to FF Built-in Module realizes the conversion function from MODBUS Protocol to Foundation Fieldbus F1 Protocol. Modbus to FF Built-in Module is one of the Microcyber M-serise modules,which have features of same size,same interface,easy to upgrade and easy to configure

    Email Details
  • Hot
    MODBUS To DP Module

    MODBUS To DP Module

    M0306 Modbus to DP Module
    1. Size: 42mm*65mm
    2. Modbus-RTU master station, PROFIBUS DP slave station
    3. Comply with PROFIBUS DPV0 protocol
    4. Electrical interface connected with Modbus-RTU slave is TTL level
    5. Can set PROFIBUS DP slave station address via DIP switch
    5. Same hardware, M0006 custom protocol to DP module

    Email Details
  • Hot
    MODBUS To HART Module

    MODBUS To HART Module

    MODBUS To HART Module/M0310 General Instroduction
    Microcyber Corporation has customized many built-in protocol converting modules for the majority of field device manufacturers, supporting to connect MODBUS RTU protocol (hereinafter referred to as “MODBUS” protocol) slave device into a variety of fieldbus system. The function of M0310 built-in MODBUS to HART module (hereinafter referred to as "HART module") is to convert MODBUS slave device into HART slave device.
    M1100S WirelessHART Communication Module:
    1. Choose low-power chips
    2. Comply with HART7.5 standard
    3. Pass FCG WirelessHART certification
    4. Quickly integrate WirelessHART into existing equipment
    5. Safe, reliable and standard data transmission

    Email Details