NCS-TT106 Temperature Module FF H1/ PROFIBUS PA/ HART

  • NCS-TT106 Temperature Module FF H1/ PROFIBUS PA/ HART
  • NCS-TT106 Temperature Module FF H1/ PROFIBUS PA/ HART
  • NCS-TT106 Temperature Module FF H1/ PROFIBUS PA/ HART
  • NCS-TT106 Temperature Module FF H1/ PROFIBUS PA/ HART
  • NCS-TT106 Temperature Module FF H1/ PROFIBUS PA/ HART
  • video
NCS-TT106 Temperature Module FF H1/ PROFIBUS PA/ HART
  • Microcyber
  • China
  • In Stock
  • 500 Sets/Month

NCS-TT106 Temperature Module supports FF Hl, PROFIBUS PA and HART protocoIs and multiple temperature sensors. With independent R&D communication controller, it has become a fieldbus temperature transmitter with high performance.

NCS-TT106 Temperature Module: 

NCS-TT106 smart temperature module, using the fieldbus technology, is a new generation of smart fieldbus temperature transmitter and it is an indispensable field device for process control. NCS-TT106 transmitter integrates abundant function blocks and realizes not only general measurement function but also complicated control strategy.



NCS-TT106 uses digital technology, so it can connect with many types of thermocouple and thermo resistive sensors. It has wide range and simple interface between field and control room, which reduces the expense of installation, operation and maintenance. 


NCS-TT106 supports HART, FF, and PA protocols. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc.


NCS-TT106 Temperature ModuleFeatures:

Support multiple thermal resistances and thermocouples

Thermal resistance supports2/3-wire connection mode

Thermocouple can use cold end compensation function


NCS-TT106 Temperature Module Basic Parameters:

Bus Power Supply: 9~32VDC  

Current consumption (static):≤14mA(FF/PA)

11V~35 VDC(HART) Input Signal: Pt100, Pt1000, Cu50, Cu100 Ω, 0, 0 to 500 ~ 4000 Ω Resistance, B, E, J, N, K, R, S, T eight degrees of Thermocouple, -100mV ~ 100mV Voltage Signal

The Channel Number: Single Channel

Fieldbus Protocol: FF/PA/HART

Insulation: Between the Terminal and the Housing:500Vrms(707VDC)

Operating Temperature: -40℃~85℃

Humidity Range: 0%~95%RH

Starting Time: ≤5secs.

Turnover Time: 0.5secs.

Electromagnetic Compatibility: In Line with the GB/T 18268-2010

Explosion-Proof Sign: Ex ia IIC T4 Ga (HART)


Structural Parameter:

Dimensions: Φ45*23mm

Shell Material: Nylon


Thermal resistance technical index

RTD Normal temperature accuracy index(25℃)

Signal type

Range

Recommended range(℃)

Accuracy

Temperature drift (per ℃)

Resistance signal

0~500Ω

0~500Ω

±0.04Ω

±0.001Ω

0~4000Ω

0~4000Ω

±0.35Ω

±0.015Ω

PT100

-200~850℃

-200~850℃

±0.15℃

±0.003℃

PT1000

-200~850℃

-200~850℃

±0.15℃

±0.005℃

CU50

-50~150℃

-50~150℃

±0.15℃

±0.005℃

CU100

-50~150℃

-50~150℃

±0.10℃

±0.003℃


Thermocouple Parameter at Normal Temperature (25℃)


Signal Type

Suggested Range (℃)

Accuracy

mV

-100Mv~100mV

0.05%

B

500℃~1810℃

±1.0℃

E

-200℃~1000℃

±0.4℃

J

-190℃~1200℃

±0.4℃

K

-200℃~1372℃

±0.4℃

N

-190℃~1300℃

±0.8℃

R

0℃~1768℃

±1.0℃

S

0℃~1768℃

±1.0℃

T

-200℃~400℃

±0.4℃



Dimension:

Temperature Transducer HART


Installation:

Via positioning hole, use two screws to install the temperature module to temperature housing or rail.



temperature transmitter pt100



How To Choose NCS-TT106 Temperature Module?

Selection Code Table

temperature transmitter with display


Wiring:

Temperature Transducer HART

Fieldbus temperature module's power and bus signal share a pair of cable, and it is called bus cable. It is suggested the user use fieldbus special cable recommended by IEC61158-2.

The signal cable and bus cable cannot share wires or wire slot with other device power wire, and they shall be away from device with high power.

The shielded wires of bus ends shall be connected to the ground.


Related Products---NCS-TT106 Temperature Module:

temperature transmitter pt100temperature transmitter with displayTemperature Transducer HARTtemperature transmitter pt100

FAQ

Q: What's Temperature Transmitter 2-wire zero point calibration configuration?

A: For 2-wire measurement, 2-wire zero point calibration can be realized by modifying transducer block TWO_WIRES_COMPENSATION parameter.

 

Q: Can I get the electronic manual?

A: Yes, please contact us.

 

Q: What type of cable should I use for wiring?

A: Fieldbus temperature module’s power and bus signal share a pair of cable, and it is called bus cable. It is suggested the user use fieldbus special cable recommended by IEC61158-2.

 

Q: Can you provided OEM service?

A: Yes, we can, such as communication board, we can also provided fieldbus development toolkit.