Profibus DP OEM Service
- Microcyber
- China Shenyang
- In Stock
- 500 Sets/Month
OEM SERVICE.Microcyber provides the PROFIBUS DP communication board customized as customer's requirements. This solution can upgrade the traditional instrument to PROFIBUS DP instrument rapidly.
1. OEM service
2. Certification pre-test support
3. Certification test support
4. System integration test support
5. Same hardware for FF H1 & PROFIBUS PA
6. FISCO certified
Product Overview
Microcyber provides the PROFIBUS DP communication board customized as customer's requirements. This solution can upgrade the traditional instrument to PROFIBUS DP instrument rapidly. The board supports bus communication, control and integration in fieldbus controller, stack, function block and interface circuit. Microcyber can assist customer in passing certification test of PNO and integration test with all kind of DCS system.
Compliant with Standard Industrial Protocols
Fully compliant with the PROFIBUS DP communication protocol and compatible with FDT 2.0, ensuring seamless integration of the device with standard management systems and meeting the unified needs of modern factories for equipment information management.
Convenient Parameter Setting Experience
Provides an intuitive online and offline parameter configuration interface, offering simple and convenient operation and greatly improving user efficiency in field commissioning and maintenance.
Flexible to Meet Customized Needs
Supports in-depth customization of special functions based on specific customer processes or application scenarios, providing a solid technical foundation for your exclusive solutions.
Widely Compatible with Mainstream Applications
Perfectly compatible with mainstream FDT framework applications on the market, such as fdtCONTAINER and PACTware, ensuring plug-and-play and rapid deployment of the device in existing systems.
Software & Firmware Design and Development includes:
Hardware:
Support ATMEL AT91SAM7SE512 processor, integrate 512K FLASH and 32K RAM
Use VPC3+C protocol controller
Support DPV0, DPV1 and DPV2 slave station function
19.2k~12M baud rate self-adaption
DP slave station address setting via DIP switch
LED status indication: indicates bus and module status
Selective terminal resistance
Working temperature: -40~85℃
Can be customized
Intrinsically safety: passed FISCO
EMC compliance
Software:
Support function block AI,AO,DI and DO
Customized transducer blocks
Provide EDD and GSD file
Technical Service:
Certification Pre-Test
PNO Certification test support