MCAFD4/8/12 Active Fieldbus Distributor
1. MCAFD4/8/12 Active Fieldbus Distributor Bus power supply, suitable for fieldbus conforming to IEC61158-2 standard
2. MCAFD4/8/12 Active Fieldbus Distributor LED indicators for bus status
3. MCAFD4/8/12 Active Fieldbus Distributor Short circuit protection and breakdown equipment isolation
4. MCAFD4/8/12 Active Fieldbus Distributor No effect of other normal working fieldbus devices when installing or uninstalling
5. MCAFD4/8/12 Active Fieldbus Distributor Low installation cost, simple electric maintenance, waterproof and dust proof of housing joint

MCAFD4/8/12 Active Fieldbus Distributor Product Overview

MCAFD series active fieldbus distributors are suitable for FF-H1 and PROFIBUS PA fieldbus applications. Field devices are connected to the system through the distributor in a trunk branch topology. Each MCAFD4/MCAFD8/MCAFD12 distributor has 4/8/12 branches, with built-in automatic bus terminals. LED status indication can quickly diagnose the short circuit status of main lines and branch lines, automatically isolate fault sections, and the distributor has multiple protection functions to ensure safe operation of the system.



MCAFD4/8/12 Active Fieldbus Distributor Feature

  • Applicable to FOUNDATION Fieldbus H1 and PROFIBUS PA  

  • LED indicator fault diagnosis

  • Power supply through field bus

  • Automatic bus terminal

  • Reverse wiring protection

  • Automatic isolation of fault ports

  • IP code: IP67

  • Applicable to Zone 2 and safety zone


MCAFD4/8/12 Active Fieldbus Distributor Details

active fieldbus distributors

Example: FF bus system composed of fieldbus distributor


PROFIBUS PA Junction Box

Example: PA bus system composed of fieldbus distributor


MCAFD4 Active Fieldbus Distributor Specification

Power Consumption

No load current power consumption

<10mA

Power consumption

<180mW

Interface

PROFIBUS PA

FOUNDATION Fieldbus H1

Main Line

Number of electrical connectors

2

Electrical connector

M16*1.5 increased safety gland

Cable diameter

4~9mm

Cross section of wire

0.2~2.5mm2

Wiring terminals

Spring type PCB terminal block (3-pin)

Rated voltage

10~32VDC

Rated current

≤1A

Main line pressure drop

<0.3V

Automatic bus termination

Branch Line

Number of electrical connectors

4

Number of on-site devices that can be connected

4

Electrical connector

M16*1.5 increased safety gland

Cable diameter

4~9mm

Cross section of wire

0.2~2.5mm2

Wiring terminals

Spring type PCB terminal block (3-pin)

Branch output voltage

≤32VDC

Maximum output current of branch line

60±0.5mA

Short circuit protection current

<800uA

Main and branch line pressure drop

<1V

Environmental

Working temperature

-40℃~+70 ℃

Storage temperature

-40 ℃~+85 ℃

Relative humidity

5%RH~5%RH

Protection level

IP67

Ex

Ex ec ic IIC T4 Gc

Size and Weight

Size (WxHxD) (mm)

170x80x145

Weight (kg)

1.5


MCAFD8 Active Fieldbus Distributor Specification

Power Consumption

No load current power consumption

<15mA

Power consumption

<250mW

Interface

PROFIBUS PA

FOUNDATION Fieldbus H1

Main Line

Number of electrical connectors

2

Electrical connector

M16*1.5 increased safety gland

Cable diameter

4~9mm

Cross section of wire

0.2~2.5mm2

Wiring terminals

Spring type PCB terminal block (3-pin)

Rated voltage

10~32VDC

Rated current

≤1A

Main line pressure drop

<0.3V

Automatic bus termination

Branch Line

Number of electrical connectors

8

Number of on-site devices that can be connected

8

Electrical connector

M16*1.5 increased safety gland

Cable diameter

4~9mm

Cross section of wire

0.2~2.5mm2

Wiring terminals

Spring type PCB terminal block (3-pin)

Branch output voltage

≤32VDC

Maximum output current of branch line

60±0.5mA

Short circuit protection current

<800uA

Main and branch line pressure drop

<1V

Environmental

Working temperature

-40℃~+70 ℃

Storage temperature

-40 ℃~+85 ℃

Relative humidity

5%RH~95%RH

Protection level

IP67

Ex

Ex ec ic IIC T4 Gc

Size and Weight

Size (WxHxD) (mm)

260x100x145

Weight (kg)

2.4

 

MCAFD12 Active Fieldbus Distributor Specification

Power Consumption

No load current power consumption

<20mA

Power consumption

<350mW

Interface

PROFIBUS PA

FOUNDATION Fieldbus H1

Main Line

Number of electrical connectors

2

Electrical connector

M16*1.5 increased safety gland

Cable diameter

4~9mm

Cross section of wire

0.2~2.5mm2

Wiring terminals

Spring type PCB terminal block (3-pin)

Rated voltage

10~32VDC

Rated current

≤1A

Main line pressure drop

<0.3V

Automatic bus termination

Branch Line

Number of electrical connectors

12

Number of on-site devices that can be connected

12

Electrical connector

M16*1.5 increased safety gland

Cable diameter

4~9mm

Cross section of wire

0.2~2.5mm2

Wiring terminals

Spring type PCB terminal block (3-pin)

Branch output voltage

≤32VDC

Maximum output current of branch line

60±0.5mA

Short circuit protection current

<800uA

Main and branch line pressure drop

<1V

Environmental

Working temperature

-40℃~+70 ℃

Storage temperature

-40 ℃~+85 ℃

Relative humidity

5%RH~95%RH

Protection level

IP67

Ex

Ex ec ic IIC T4 Gc

Size and Weight

Size (WxHxD) (mm)

260x100x145

Weight (kg)

2.4