NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)

  • NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • video
NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
  • Microcyber
  • Liaoning, China
  • In Stock
  • 500 Sets/Month

NCS-PT105IIS PA/FF Protocol Pressure Transmitter
1.High accuracy: ±0.0075%FS(20℃,range rate10:1)
2.Multi sensor:gauge pressure(SG),Absolute pressure (SA)
3.Measurement media:liquid,gas and stream
4.Explosion-proof level:IP65
5.Long time stability:In 12 months, ±0.1% of maximum range

fieldbus head mount temperature transmitter

NCS-PT105IIS series Smart Pressure Transmitter with advanced, mature, reliable Piezoresistive Silicon Sensors has been designed meticulously by combining advanced microprocessor technology and digital capacitance measurement techniques. Its LCD can display many physical parameters such as pressure, temperature, current. It can be realized zero adjustment, range settings and other features by key-press operation, and easy to on-site tests.


NCS-PT105IIS series Smart Pressure Transmitter supports HART, FF H1, Profibus PA, Profibus DP protocol and can measure pressure, differential pressure, liquid level, flow, and other industrial parameters. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc.


pressure transmitter fieldbus


NCS-PT105IIS series Smart Pressure Transmitter Specification:


Basic Parameter

Measure object

liquid、gas、stream


Power

9~32V dc (FF 、 PA) 9~17.5VDC (FF、PA; explosion-proof) 11.9~42VDC (HART)
11.9~30VDC (HART; explosion-proof)
Output
Analog:2 wire 4~20mA
Digital:HART,FF and PA signal
Load resistant
0~1500ohm (common)
250~550ohm (use HART)
Insulation
Voltage between terminal and housing:500Vrms (707VDC)
Display
Optional 6 bits digital number or 5 bits characters LCD display
Temperature
Work temperature: -40 ~ 85℃ (without display)
-30 ~ 70℃ (with display)
-30 ~ 60℃(explosion-proof IC)
Store temperature: -40 ~ 100℃ (without display)
-40 ~ 85℃ (with display)
Humidity scale
5%~100%RH
Start time
≤ 5 seconds
Refresh time
0.2 seconds
Dump adjusting
Constant of time 0~15 seconds
Performance Specification
Precision
±0.075% of the select range. If the select range <1/10 maximum of the range, the precision is ±[0.025+0.005× (maximum range/select
range)]% of select range
Temperature Effect
Effect of every change of 28℃ (50℉)
Select range ≥0.1 maximum range:±[0.019% of maximum range +0.125% of select range] ;
Select range <0.1 maximum range:±[0.025% of maximum range+0.125%
of select range].
Long Time Stability
In 12 months, ±0.1% of maximum range
Static Pressure Effect
±0.25%/13.8MPa of maximum range
Location Installed Effect
The maximum of the zero point movement is 0.24kPa
Power Effect
< 0.005%/V of range calibrated
Explosion-proof
intrinsically safety Ex ia II C T4
Proof Level
IP65
Vibration Effect
IEC 60068-2-6 Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)





Electromagnetic Compatibility
IEC 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity
test
IEC 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency,
electromagnetic field immunity test
IEC 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst
immunity test
IEC 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted
disturbances, induced by radio-frequency fields
IEC 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field
immunity test


NCS-PT105IIS series Smart Pressure Transmitter Dimension&Structure:


Fieldbus Instruments
fieldbus head mount temperature transmitter
pressure transmitter fieldbus
Fieldbus Instruments
Packing & Delivery
fieldbus head mount temperature transmitter
pressure transmitter fieldbushttps://www.microcyber-fieldbus.com/