NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter

  • NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter
  • NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter
  • NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter
  • NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter
  • NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter
NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter
  • Microcyber
  • Shenyang,China
  • In Stock
  • 500 pieces per month

NCS-TT108M Series Intelligent Temperature Transmitter is an eight-channel DIN-rail mounted temperature transmitter designed to meet the demands of multi-point temperature measurement in industrial field applications.
It supports a wide range of sensors, including various types of RTDs (Resistance Temperature Detectors), thermocouples (TC), resistance (Ω), and voltage (mV) inputs, and is compatible with the Modbus communication protocol.
The product is widely applied in process industries such as petroleum, chemical, power, and metallurgy.
1. Supports RTD, TC, mV, Ω Modbus-RTU protocol compliant
2. 8 channels 2/3-wire RTD connection supported
3. LCD display & local configuration via keypad

NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter Product Overview:

NCS-TT108M Series Intelligent Temperature Transmitter is an eight-channel DIN-rail mounted temperature transmitter designed to meet the demands of multi-point temperature measurement in industrial field applications.

It supports a wide range of sensors, including various types of RTDs (Resistance Temperature Detectors), thermocouples (TC), resistance (Ω), and voltage (mV) inputs, and is compatible with the Modbus communication protocol.

The product is widely applied in process industries such as petroleum, chemical, power, and metallurgy.


NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter Features:

  • Standardized Communication:Utilizes the Modbus-RTU protocol via an RS485 interface to ensure reliable, widely compatible, and cost-effective digital communication.

  • High-Density Input:Features8-channel inputsupporting various RTD, thermocouple, resistance, and voltage signals, with 2-wire and 3-wire connection support for RTDs.

  • High-Precision Measurement:Pt100 accuracy is better than Class 0.1 at room temperature, and thermocouple cold junction compensation accuracy reaches ±1℃.

  • Intuitive Local Interface:Equipped with an LCD display and push-buttons, enabling convenient real-time monitoring and local parameter configuration without external tools.

  • Advanced Diagnostics:Built-in sensor open-circuit and short-circuit detection capabilities assist in rapid fault identification and maintenance.


NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter Wiring diagram:


Multimchannel Sensor Input Temperature Transmitter


NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter Parameters:

Input Signal

Pt100, Pt1000, CU50, CU100 (4 types RTD) 0~500Ω, 0~4000Ω resistance
B, E, J, N, K, R, S, T (8 types thermocouple) -100mV~100mV voltage signal

Number of Channels

8 Channels

RTD Wiring

2, 3-wire

Working Power Supply

24 V DC (-15% ~ +20%) Current consumption: ≤ 180 mA

Bus Interface

RS-485 (EIA/TIA-485)

Bus Protocol

MODBUS RTU

Transmission Rate

1200bps, 2400bps, 4800bps, 9600bps, 14400bps, 19200bps (Default 9600bps)

Addressing Mode

Configured by buttons or master, subject to the latest configuration

Isolation

500Vrms (707VDC), between Input channels, Bus, Power, and Ground.
No isolation between two temperature input channels within the module.

Operating Temperature

-20℃ ~ 70℃ (With LCD display) -40℃ ~ 85℃ (No display)

Humidity Range

0% ~ 95%RH, non-condensing

Start Time

≤5 seconds

Update Time

0.8 seconds

Vibration Test

5~150Hz, 3.5mm displacement, 5g acceleration

Protection Level

IP20 Outdoor housing: IP65

EMC

Complies with GB/T 18268-2010 Table 2 requirements


Signal Type

Suggested Range (℃)

Accuracy

Resistance

0~500Ω,0~4000Ω

±0.05%

PT100

-200~850℃

±0.2℃

PT1000

-200~850℃

±0.1℃

CU50

-50~150℃

±0.3℃

CU100

-50~150℃

±0.2℃

mV

-100Mv~100mV

0.05%

B

500℃~1810℃

±1.0℃

E

-200℃~1000℃

±0.4℃

J

-190℃~1200℃

±0.4℃

K

-200℃~1372℃

±0.4℃

N

-190℃~1300℃

±0.8℃

R

0℃~1768℃

±1.0℃

S

0℃~1768℃

±1.0℃

T

-200℃~400℃

±0.4℃

mV

-100Mv~100mV

0.05%

B

500℃~1810℃

±1.0℃

E

-200℃~1000℃

±0.4℃

J

-190℃~1200℃

±0.4℃

K

-200℃~1372℃

±0.4℃

N

-190℃~1300℃

±0.8℃

R

0°C ~ 1768°C

±1.0°C

S

0 °C~ 1768°C

±1.0°C

T

-200°C ~ 400°C

±0.4°C


NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter Size:

thermocouple sensors

NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter Certification:


temperature acquisition modules


NCS-TT108M Rail Mounted Multi-Input Modbus Temperature Transmitter Packaging&Shipping


Multimchannel Sensor Input Temperature Transmitter

Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right