MODBUS To HART Gateway
- Microcyber
- Liaoning, China
- ASAP
- 1000 units per month
G0310 Modbus to HART Gateway, designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output.
1. Comply with standard HART 7.9 and Modbus-RTU protocols
2. Support 6 device variables and 4 dynamic variables
3. DIN rail mounting and provide DD and DTM files for easy system integration.
G0310 MODBUS To HART Gateway Brief Instruction
G0310 Modbus to HART Gateway, designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output.
G0310 MODBUS To HART Gateway Size

G0310 MODBUS To HART Gateway Structure

G0310 MODBUS To HART Gateway Basic Parameter
Measurement Object | Modbus RTU slave device |
Power | 12~42VDC |
Bus Protocol | 2-wire,4~20mA+HART |
Load resistance | 0~1500Ω(4~20mA) |
230~1100Ω(HART communication) | |
Isolation Voltage | Modbus and HART bus interface,500VAC |
Temperature Range | -40℃~85℃ |
Humility Range | 5~95%RH |
Start Time | ≤5s |
Refresh Time | 0.2s |
Damping adjustment | Time constant 0~32s |
The G0310 is a DIN-rail-mounted gateway that converts between Modbus RTU and HART protocols. As one of the Microcyber G-series protocol conversion gateways, it can seamlessly integrate existing Modbus devices into HART bus networks.
The power supply of G0310 MODBUS to HART gateway is HART bus, and 485 communication need external 24V power supply. The recommended is TP cable, and it shall improve device's anti-electromagnetic interference ability. G0310 MODBUS to HART gateway connection diagram is shown as in Figure:

G0310 MODBUS to HART Gateway supports 4 dynamic variables, 6 device variables.Via MODBUS register, the data selected by MODBUS device is configured to device variables of G0310 MODBUS to HART Gateway, and then,it enters the mapping from device variable to dynamic variable, as the device output, supporting 4~20mA analog signal output.G0310 MODBUS to HART Gateway functional block diagram is shown as :

G0310 MODBUS To HART Gateway Features
Be tallied with HART7.0
HART slave and Modbus master mode
4~20mA analog signal overlay HART digital signal
Support 1 Modbus slave device
Support 6 device variables and 4 dynamic variables
Configure gateway by HART interface
Write protect user data
Support high/low alarm current
RS485 Modbus interface
LED power and communication indicating
Standard DIN rail installation
G0310 MODBUS To HART Gateway Application
Microcyber passes the Authentication of ISO 9001 Quality System, and has an outstanding innovative R&D team,plentiful practical experiences of design of the Automatic engineering, a leading product series, a huge market network, a strict quality management system and an excellent enterprise culture. All these further a solid foundation of entrepreneurship and sustainable development for Microcyber.

G0310 MODBUS To HART Gateway Package and Delivery