G0306 Brief Instruction
This gateway realizes the conversion function from Modbus RTU to PROFIBUS DP, making multiple slave station devices that conform to Modbus RTU communication regulation access to PROFIBUS DP network.
1. Modbus-RTU protocol to PROFIBUS DP protocol
2. Standard DP interface, baud rate self-adapting, support up to 12Mbps
3. Support up to 244 byte input/output
4. Configure Modbus communication parameters by GSD
5. Modbus side can be both master and slave station

G0306 MODBUS To DP Gateway Brief Instruction:

This gateway realizes the conversion function from Modbus RTU to PROFIBUS DP, making multiple slave station devices that conform to Modbus RTU communication regulation access to PROFIBUS DP network. 

Product name: Modbus to DP gateway

Product number:G0306

This gateway realizes the conversion function from Modbus RTU to PROFIBUS DP. Multiple slave devices that comply with the Modbus RTU communication rules can be connected to the PROFIBUS DP network. The Modbus

end can be used as a master station or as a slave station. This function can be switched by special function keys.


G0306 MODBUS To DP Gateway Size:

MODBUS To DP Gateway

G0306 MODBUS To DP Gateway Working Principle:

G0306 Modbus to DP Gateway supports both Modbus RTU and PROFIBUS DP. As PROFIBUS DP slave device, itcan connect at most 31 Modbus slave station into PROFIBUS PA network theoretically ( it should be 485 bus environment, and we suggest less than 10 Modbus slave device to ensure communication quality).


G0306 MODBUS To DP Gateway Features:

  • Support 31 Modbus RTU slave devices at most

  • Be tallied with PROFIBUS-DP/V0 protocol stipulations

  • Support 244 input, 244 output, 244 parameters at most

  • Modbus RTU and PROFIBUS DP configured flexibly by GSD files

  • Transparent data transfer of Modbus RTU and PROFIBUS DP

  • PROFIBUS DP address set up by hardware

  • 35mm rail, easy to install

  • Frequency converter, motor start protection device, transmitters, intelligent measuring device and instrument, etc. with MODBUS protocol interface


G0306 MODBUS To DP Gateway Details:

DP Gateway

Equipment classification:

This gateway is divided into two models according to the Modbus interface (consistent with the actual selection):

Product modelModbus interface
GW-MODB-DP-RS485RS485
GW-MODB-DP-RS232RS232


This gateway is distinguished according to the communication method (function distinction, use the following name to facilitate document description, not the actual selection, see the appendix for the actual selection): 

Product modelModbus sidePROFIBUS side
G0306-MSMaster stationSlave station
G0306-SSSlave stationSlave station


 Note: 1) The V1.0 version only implements the GW-MODB-DP-RS485 version, and the GW-MODB-DP-RS232http://www.microcyber.cn/en ~ 2 ~ version will be added later, so stay tuned. 

             2) G0306 Modbus to DP gateway can switch freely between G0306-MS and G0306-SS through special function buttons according to user needs, see 2.2.7 for the switching method.


G0306 MODBUS To DP Gateway Basic Parameter:

Working Voltage

24VDC(±20%)

Rated Current

I24V:≤60mA

Working Temperature

-20℃~70℃

Storage Temperature

-40℃~70℃

Humidity Range

5%~95%RH

Modbus Physical Interface

RS485 (Configurable Terminal)/ RS232

Modbus Character Transfer Mode

RTU mode