LinkMaster Function Modbus to FF Gateway
- Microcyber
- Liaoning, China
- ASAP
- 1000 units per month
LinkMaster Function Modbus to FF Gateway.G0313 Modbus to FF Gateway is a gateway device of Modbus protocol and FF protocol developed by Microcyber.
1. Modbus-RTU protocol to FF H1 protocol
2. Comply with FF H1 protocol
3. Support LinkMaster function
4. Support standard DD specification
5. Support up to 4 Modbus devices
G0313 Modbus to FF Gateway Brief Introduction
G0313 Modbus to FF Gateway is a gateway device of Modbus protocol and FF protocol developed by Microcyber. As Modbus master station, G0313 Modbus to FF Gateway communicates with Modbus-RTU device via RS485 interface, and it can convert the data of Modbus-RTU device to FF device variable output.
G0313 Modbus to FF Gateway Size

G0313 Modbus to FF Gateway Structure

The G0313 is a DIN-rail-mounted gateway that converts between Modbus RTU and FF protocols. As one of the Microcyber G-series protocol conversion gateways, it can seamlessly integrate existing Modbus devices into FF bus networks.
G0313 Modbus to FF Gateway Features
Support 4 Modbus RTU slave devices’access at most
Support AI/AO/DI/DO, each support 8 channels
1 Modbus transducer block
4 PID function blocks
1 RES function block tallied with FF standard
Modbus RTU device upgrade
Side wiring diagram and parameter description
DIN rail installation
Support Modbus-RTU protocol conversion to FF protocol, supporting up to 4 Modbus slave devices.
Support ITK 6.5.0, function block diagnostics, and Link Master functionality.
Support multiple function blocks including AI, AO, DI, DO, and PID.
Modbus to FF gateway is a gateway device supporting Modbus and FF protocol. As FF device, it can communicate with Modbus devices, read Modbus data to FF device by simply configuration,and transfer data to control system through FF bus. System Wiring Diagram of Modbus to FF Gateway is shown

Modbus to FF Gateway supports 4 Modbus slave devices, 8 groups of analog input output and discrete input output parameters, totally 32 channels provided. It configures Modbus device's data into transducer block’s parameters via Modbus register, and provides data support for FF system via channels between variables and AI, AO, DI and DO function blocks. Principle Diagram for MODBUS to FF Gateway is shown

G0313 Modbus to FF Gateway Basic Parameter
Working Temp. | -20 ... +70 °C |
Storage Temp. | -40 °C ... +85 °C |
Power Supply | 9 … 36 V / 14 mA@ 24 V |
Dimension (L x W x H) | 114.5 x 22.5 x 99 mm (without connector) |
Interface | RS485 |
Indicator Light | SYS, APL, L/A, Rx/Tx, bus-specific |
EMC | GB/T 18268.1 |
Noise Interference | GB 9254 |
Installation | DIN-Rail, EN-50022 35mm x 7,5mm |
G0313 Modbus to FF Gateway Application
Microcyber passes the Authentication of ISO 9001:2008 Quality System and automotive industry ISO/TS16949 quality system certification. We have laid a solid foundation for the company's entrepreneurship and sustainable development with excellent R & D team, rich experience in automation engineering design and implementation, industry leading products, huge market network and excellent corporate culture.

G0313 Modbus to FF Gateway Package and Delivery