LinkMaster Function Modbus to FF Gateway

  • LinkMaster Function Modbus to FF Gateway
  • LinkMaster Function Modbus to FF Gateway
  • LinkMaster Function Modbus to FF Gateway
  • LinkMaster Function Modbus to FF Gateway
  • video
LinkMaster Function Modbus to FF Gateway
  • Microcyber
  • Liaoning, China
  • ASAP
  • 1000 units per month

LinkMaster Function Modbus to FF Gateway.G0313 Modbus to FF Gateway is a gateway device of Modbus protocol and FF protocol developed by Microcyber.
1. Modbus-RTU protocol to FF H1 protocol
2. Comply with FF H1 protocol
3. Support LinkMaster function
4. Support standard DD specification
5. Support up to 4 Modbus devices

G0313 Modbus to FF Gateway Brief Introduction

G0313 Modbus to FF Gateway is a gateway device of Modbus protocol and FF protocol developed by Microcyber. As Modbus master station, G0313 Modbus to FF Gateway communicates with Modbus-RTU device via RS485 interface, and it can convert the data of Modbus-RTU device to FF device variable output.



G0313 Modbus to FF Gateway Size

MODBUS To FF Converter

G0313 Modbus to FF Gateway Structure

Modbus master station gateway

The G0313 is a DIN-rail-mounted gateway that converts between Modbus RTU and FF protocols. As one of the Microcyber G-series protocol conversion gateways, it can seamlessly integrate existing Modbus devices into FF bus networks.


G0313 Modbus to FF Gateway Features

  • Support 4 Modbus RTU slave devices’access at most

  • Support AI/AO/DI/DO, each support 8 channels

  • 1 Modbus transducer block

  • 4 PID function blocks

  • 1 RES function block tallied with FF standard

  • Modbus RTU device upgrade

  • Side wiring diagram and parameter description

  • DIN rail installation

  • Support Modbus-RTU protocol conversion to FF protocol, supporting up to 4 Modbus slave devices.

  • Support ITK 6.5.0, function block diagnostics, and Link Master functionality.

  • Support multiple function blocks including AI, AO, DI, DO, and PID.


Modbus to FF gateway is a gateway device supporting Modbus and FF protocol. As FF device, it can communicate with Modbus devices, read Modbus data to FF device by simply configuration,and transfer data to control system through FF bus. System Wiring Diagram of Modbus to FF Gateway is shown 


RS485 to FF Gateway


Modbus to FF Gateway supports 4 Modbus slave devices, 8 groups of analog input output and discrete input output parameters, totally 32 channels provided. It configures Modbus device's data into transducer block’s parameters via Modbus register, and provides data support for FF system via channels between variables and AI, AO, DI and DO function blocks. Principle Diagram for MODBUS to FF Gateway is shown 


MODBUS To FF Converter


G0313 Modbus to FF Gateway Basic Parameter

Working Temp.

-20 ... +70 °C

Storage Temp.

-40 °C ... +85 °C

Power Supply

9 … 36 V / 14 mA@ 24 V

Dimension (L x W x H)

114.5 x 22.5 x 99 mm (without connector)

Interface

RS485

Indicator Light

SYS, APL, L/A, Rx/Tx, bus-specific

EMC

GB/T 18268.1

Noise Interference

GB 9254

Installation

DIN-Rail, EN-50022 35mm x 7,5mm


G0313 Modbus to FF Gateway Application

Microcyber passes the Authentication of ISO 9001:2008 Quality System and automotive industry ISO/TS16949 quality system certification. We have laid a solid foundation for the company's entrepreneurship and sustainable development with excellent R & D team, rich experience in automation engineering design and implementation, industry leading products, huge market network and excellent corporate culture.


Modbus master station gateway

G0313 Modbus to FF Gateway Package and Delivery


RS485 to FF Gateway


Get the latest price? We'll respond as soon as possible(within 12 hours)