HART To MODBUS Gateway

  • HART To MODBUS Gateway
  • HART To MODBUS Gateway
  • HART To MODBUS Gateway
  • HART To MODBUS Gateway
  • HART To MODBUS Gateway
  • video
HART To MODBUS Gateway
  • Microcyber
  • Liaoning, China
  • ASAP
  • 1000 units per month

The G1003 is a DIN-rail-mounted gateway that converts between HART and Modbus RTU protocols. As one of the Microcyber G-series protocol conversion gateways, it can seamlessly integrate existing HART devices into Modbus bus networks.
1. HART protocol to Modbus-RTU/ASCII protocol
2. Hardware interface RS232/422/485
3. Configured as HART first master device or second master device
4. Can work in a point-to-point or multipoint mode
5. Connect up to 15 HART slave devices in multipoint working mode
6. All supported HART commands can be configured
7. Support HART burst mode

G1003 HART To MODBUS Gateway Product Description


HART To MODBUS Gateway

G1003 HART To MODBUS Gateway Brief Instruction

G1003 gateway realizes protocol converting from HART to Modbus RTU / ASCII. Supporting to connect multi HART slave devices into Modbus network. In the gateway, HART terminal is master station, Modbus terminal is slave station. 


G1003 HART To MODBUS Gateway Features & Structure

The G1003 is a DIN-rail-mounted gateway that converts between HART and Modbus RTU protocols. As one of the Microcyber G-series protocol conversion gateways, it can seamlessly integrate existing HART devices into Modbus bus networks.

  • Be tallied with HART7.0

  • HART master and Modbus slave mode

  • 4~20mA analog signal overlay HART digital signal

  • Support 15 HART slave device

  • Configure gateway by special software

  • Write protect user data

  • RS485 Modbus interface

  • LED power and communication indicating

  • Standard DIN rail installation


G1003 HART To MODBUS Gateway Size

HART to Modbus Gateway


G1003 HART To MODBUS Gateway Structure

Gateway

G1003 HART To MODBUS Gateway Connection


HART To MODBUS Gateway

G1003 HART To MODBUS Gateway Function overview

The HART to Modbus gateway contains a HART master channel and a Modbus slave channel. HART master channel is in charge of obtaining HART slave data in HART network, and write the obtained data into data area inside the gateway; Modbus slave channel is responsible for receiving request from Modbus master station, including requests during configuring gateway parameter and loop reading data area inside the gateway; By the HART to Modbus gateway, easily realize the function that Modbus master station accesses to HART network data.


G1003 HART To MODBUS Gateway Basic Parameter


Parameter

Value

Working Temp.

-20 ... +70 °C

Storage Temp.

-20 ... +70 °C

Power Supply

9~30VDC

Dimension (L x W x H)

114.5 x 22.5 x 99 mm (without connector)

Modbus Interface

RS-232/RS-422/RS485

HART Interface

HART digital signal

Indicator Light

SYS, APL, L/A, Rx/Tx, bus-specific

Weight

150 g

Protocol before conversion 

HART

Protocol after conversion

Modbus

EMC

GB/T 18268.1

Noise Interference

GB 9254

Installation

DIN-Rail, EN-50022 35mm x 7,5mm


G1003 HART To MODBUS Gateway Application

The gateway works according to the configured parameters, cyclically obtaining data from slave devices in the HART network and storing it in the internal data area of the gateway. At the same time, the Modbus channel waits for requests from the Modbus master and responds; In addition, in this mode, the gateway also supports sending non cyclic HART commands to slave devices in the HART channel network through the Modbus channel. The Modbus channel communicates according to the communication parameters configured by the user.


HART to Modbus Gateway

G1003 HART To MODBUS Gateway Package and Delivery


Gateway

Get the latest price? We'll respond as soon as possible(within 12 hours)