HART To MODBUS Gateway
- Microcyber
- Liaoning, China
- ASAP
- 1000 units per month
The G1003 is a DIN-rail-mounted gateway that converts between HART and Modbus RTU protocols. As one of the Microcyber G-series protocol conversion gateways, it can seamlessly integrate existing HART devices into Modbus bus networks.
1. HART protocol to Modbus-RTU/ASCII protocol
2. Hardware interface RS232/422/485
3. Configured as HART first master device or second master device
4. Can work in a point-to-point or multipoint mode
5. Connect up to 15 HART slave devices in multipoint working mode
6. All supported HART commands can be configured
7. Support HART burst mode
G1003 HART To MODBUS Gateway Product Description
G1003 HART To MODBUS Gateway Brief Instruction
G1003 gateway realizes protocol converting from HART to Modbus RTU / ASCII. Supporting to connect multi HART slave devices into Modbus network. In the gateway, HART terminal is master station, Modbus terminal is slave station.
G1003 HART To MODBUS Gateway Features & Structure
The G1003 is a DIN-rail-mounted gateway that converts between HART and Modbus RTU protocols. As one of the Microcyber G-series protocol conversion gateways, it can seamlessly integrate existing HART devices into Modbus bus networks.
Be tallied with HART7.0
HART master and Modbus slave mode
4~20mA analog signal overlay HART digital signal
Support 15 HART slave device
Configure gateway by special software
Write protect user data
RS485 Modbus interface
LED power and communication indicating
Standard DIN rail installation
G1003 HART To MODBUS Gateway Size

G1003 HART To MODBUS Gateway Structure

G1003 HART To MODBUS Gateway Connection

G1003 HART To MODBUS Gateway Function overview
The HART to Modbus gateway contains a HART master channel and a Modbus slave channel. HART master channel is in charge of obtaining HART slave data in HART network, and write the obtained data into data area inside the gateway; Modbus slave channel is responsible for receiving request from Modbus master station, including requests during configuring gateway parameter and loop reading data area inside the gateway; By the HART to Modbus gateway, easily realize the function that Modbus master station accesses to HART network data.
G1003 HART To MODBUS Gateway Basic Parameter
Parameter | Value |
Working Temp. | -20 ... +70 °C |
Storage Temp. | -20 ... +70 °C |
Power Supply | 9~30VDC |
Dimension (L x W x H) | 114.5 x 22.5 x 99 mm (without connector) |
Modbus Interface | RS-232/RS-422/RS485 |
HART Interface | HART digital signal |
Indicator Light | SYS, APL, L/A, Rx/Tx, bus-specific |
Weight | 150 g |
Protocol before conversion | HART |
Protocol after conversion | Modbus |
EMC | GB/T 18268.1 |
Noise Interference | GB 9254 |
Installation | DIN-Rail, EN-50022 35mm x 7,5mm |
G1003 HART To MODBUS Gateway Application
The gateway works according to the configured parameters, cyclically obtaining data from slave devices in the HART network and storing it in the internal data area of the gateway. At the same time, the Modbus channel waits for requests from the Modbus master and responds; In addition, in this mode, the gateway also supports sending non cyclic HART commands to slave devices in the HART channel network through the Modbus channel. The Modbus channel communicates according to the communication parameters configured by the user.

G1003 HART To MODBUS Gateway Package and Delivery