• 1701-2022

    Overview and Features of Smart Temperature Transmitter

    Overview and Features of Smart Temperature Transmitter

  • 2308-2021

    What are the main characteristics of the intelligent temperature transmitter?

    What are the main characteristics of the intelligent temperature transmitter? When using the temperature transmitter, you need to understand a lot of characteristics, so as to make better use of its characteristics in production and use.

  • 1312-2021

    Application of Sensors and Communication Gateway in Corrosion Monitoring System

    Causes and hazards of corrosion Oil and gas pipelines, pipelines for hazardous chemicals in refineries, storage tanks, etc. will be accompanied by corrosive substances such as sulfides, water-soluble acids, and water-soluble alkalis during use. In the process of production, processing and transportation, the production equipment and transportation pipelines are corroded. Mainly occur in low-temperature parts leak corrosion, high-temperature parts sulfur corrosion, and high-temperature parts naphthenic acid corrosion, which seriously affects the safety of the device, and even causes serious economic and social impacts; lack of long-term effective online inspection of on-site equipment and pipelines It is difficult to predict the risks of existing pipelines by using data analysis to predict the life of pipelines; the intervals between overhauls are too long, and it is difficult to measure the regular corrosion of overhead pipelines. Therefore, a device capable of online corrosion monitoring of pipelines is required.

  • 2910-2021

    The importance of temperature in remote sealed pressure transmitter

    The importance of temperature in remote sealed pressure transmitter

  • 2010-2021

    Composition and technical index of diffused silicon pressure transmitter

    Composition and technical index of diffused silicon pressure transmitter

  • 1003-2021

    8-Channel Sensor Input Temperature Transmitter's Working Principle and Structure

    NCS-TT108 collects thermo resistance and thermocouple signal, which is converted into fieldbus signal after arithmetic and handling, and achieves temperature measurement functions.

  • 0407-2018

    Microcyber attended Shanghai Station FCG Symposium

    Shanghai Station FCG Symposium

  • 0207-2026

    Microcyber Intelligent Device Full Lifecycle Management Solution

    ‌1. 20+ Years of Industrial Tech Expertise, Full Compliance for Scenarios 2.3-Tier Architecture Breaks Data Silos, Enables Full-Link Intelligent Control 3.Shift from Reactive Repair to Predictive Maintenance, Cut Costs While Ensuring Safe Production

  • 1806-2026

    Microcyber NCS-TT106H Head Mounted/Hart Temperature Transmitter

    1. Converts various input signals into 4–20 mA output signals and HART signals. 2. Supports measurement of various RTDs, thermocouples, resistance and voltage signals. 3. Single-channel input; supports 2, 3, and 4-wire connections for RTDs. 4. High accuracy (Pt100: ±0.1°C), low temperature drift (Pt100: ±0.003°C/°C), analog output accuracy 0.03% FS. 5. External Pt100 for cold-junction compensation, with accuracy up to ±0.15°C. 6. Open-circuit/short-circuit detection to assist in identifying sensor faults. 7. Complies with intrinsically safe explosion-proof requirements for safe operation in hazardous areas. 8. Standard DIN Type B sensor head mounting. 9. FCG certified. 10.Provides EDD/DTM files for compatibility with various DCS systems.

Get the latest price? We'll respond as soon as possible(within 12 hours)