MODBUS To PA Gateway

  • MODBUS To PA Gateway
  • MODBUS To PA Gateway
  • MODBUS To PA Gateway
  • MODBUS To PA Gateway
  • MODBUS To PA Gateway
  • video
MODBUS To PA Gateway
  • Microcyber
  • Liaoning, China
  • ASAP
  • 1000 units per month

MODBUS To PA Gateway The product realizes the converter function from Modbus RTU to PROFIBUS PA, and it shall multiple devices with Modbus RTU protocol to PROFIBUS PA network.
1. Modbus-RTU protocol to PROFIBUS PA protocol
2. Support PA profile 3.02
3. Support GSD 5.0 specification and standard EDD specification
4. Support AI, AO, DI, DO standard function block
5. Support up to 4 Modbus devices

G0307 MODBUS To PA Gateway Brief Instruction

The product realizes the converter function from Modbus RTU to PROFIBUS PA, and it shall multiple devices with Modbus RTU protocol to PROFIBUS PA network.



G0307 MODBUS To PA Gateway Working Principle

G0307 Modbus to PA gateway is a device supporting Modbus RTU protocol and PROFIBUS PA protocol. As the PROFIBUS PA slave device, it can make 4 Modbus slave devices connect to PROFIBUS PA network. 


G0307 MODBUS To PA Gateway Size

MODBUS To PA Gateway

G0307 MODBUS To PA Gateway Features

  • Support 4 Modbus RTU slave devices’ access at most

  • Each Modbus RTU slave device is assigned 4 function blocks by default, each function block is one piece

  • Modbus RTU interface can configure bus terminal, 24VDC external power supply required

  • Support PROFIBUS PA 3.02

  • Configure PROFIBUS address by software or hardware

  • PROFIBUS PA is powered by bus

  • 4 function blocks, AI/AO/DI/DO, each is four pieces, totally 16 function blocks, ahead of similar products

  • Support GSD files, total 16 channels, each has one fixed function block, each function block can be configured a variety of modules


G0307 MODBUS To PA Gateway Details


Gateway

G0307 Modbus to PA gateway includes 1 physical block, 16 function blocks and 1 Modbus transducer block. Modbus transducer block includes 4 AIs, 4 AOs, 4 DIs and 4 DOs. The data (Modbus device data) can establish connection with function blocks via channels to realize protocol convert function.


PA Gateway


As Modbus master, G0307 Modbus to PA gateway shall do the communication with Modbus slave, and exchange Modbus transducer block parameter data and function block, so that it connect Modbus slave to PROFIBUS system.


G0307 MODBUS To PA Gateway Basic Parameter

Bus Power

9~32VDC

Modbus Power

24VDC(±20%)

Current Consumption

≤ 14mA

Working Temperature

-20℃~70℃

Storage Temperature

-40℃~70℃

Humility Range

5%~95%RH

Modbus

RS485 (configurable end) / RS232

Physical Interface


G0307 MODBUS To PA Gateway Performance Index

Protection Level

Enclosure protection grade reaches IP20




EMC

Compliance 18268.1-2010 GB / T "electrical measurements, laboratory equipment control and electromagnetic compatibility requirements of a Part : General Requirements" industrial sites immunity requirements

The FF port test method adopts GB/T 18268.23-2010 " Electromagnetic Compatibility Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 23 : Special Requirements Test configuration, workingconditions and performance judgments with integrated or remote signal conditioning transmitters according to"


G0307 MODBUS To PA Gateway Application

MODBUS To PA Gateway

G0307 Package and Delivery 

Gateway